IE-8MD
Components
Selective Call Main Handset for 2 Doors, Up To 6 Rooms
Jump to:
Features
- Selective Call or All Call between handsets
- Simple 4 conductor wiring between handsets
- Two doors with selective door release
- External doorbell can be added
- AC or DC powered (12~16V AC or 12~18V DC)
Specs
Communication
Handset (full-duplex)
Door Release
N/O dry contact, 24V AC/ DC, 350mA
Wire Type
Door Station to Master Station: 2-cond., overall shield - use Aiphone #822202
Master Station to Sub Stations: 4-cond., overall shield - use Aiphone #822206
Distance
Door Station to Master Station: 500'(22AWG) 1,180'(18AWG)
Master Station to farthest Sub Master Station: 245'(22AWG) 580'(18AWG)