Press Ctrl/Cmd + P to print
or save as PDF

Line Drawing

Specifications

Power Source

Supplied by Central Control Unit (NHX-80M)

Power Consumption

80mA Standby, 500mA Maximum

Communication

Handset or Push-to-talk

Capacity

50 Stations

Call Priority

  1. Cord-out trouble call
  2. Urgent bathroom call and NHR-3TS common area bathroom/staff call
  3. Routine call (sub station call-ins on standby connected according to urgency level and time of call)

Warning Tones

  1. Line-off trouble alert when the station is unplugged (buzzer activated at NHX-50M) – to silence, plug in CN1047 shorting connector inside NHX-80X and call for service
  2. 90 sec. elapse timer – call tone goes up to HIGH level
  3. 90 sec. off-hook timer – steady tone will notify handset is off-hook

Wiring

Master Station to Central Control Unit: 5 twisted pair, low cap, PE, overall shield — use Aiphone #862210

Wiring Distance

Master Station to Central Control Unit: 65′(22 AWG)

Mounting

Desk-top use

Operating Temperature

32° ~ 104°F (0° ~ 40°C)

Dimensions

3-1/4” H x 11” W x 8-1/4” D