Modification
LED monitoring indicator on an LE series sub station. This modification allows users to know that their station is being monitored by a master station.
Difficulty Level
5 – Hard – circuit creation and internal addition.
Components Required
- Resistor: 1K Ω, 0.25 W
- LED: general purpose
Instructions
- Run two extra wires to each sub station requiring the modification. (Only one extra wire is required when using LE-C, LE-CN, or LE-DL.)
- Install LED and resistor as shown on diagram.
- When a master station selects that sub station, the LED will illuminate.
- No physical provisions are made on the sub station for the addition of an LED. Chassis modification or external mounting is required.
Diagram
Notes:
- Inside the sub station, install the general-purpose LED and 1K Ω resistor as shown above.
- Since there is no designated location for placement of the LED, either modify the chassis of the sub station or mount the LED externally.
- The LE-C, LE-CN and LE-DL already have the “+” wire connected to them. Only the “K” wire will need to be added with those models.