Summary
Triggering Relay Output 2 on an IX Series door station from an IX-MV7-* speed dial for secondary door release (gate/mantrap/sally port/vestibule).
Solution
To enable the second relay on the back of the door station:
- Click Station View (top left corner), expand Relay Output on the left-hand menu and select Option Input/Relay Output Settings.
- At the top of the screen, use the drop-down to select the station number of the door station to be configured under Select Station to Edit, and click Select.
- Use the drop-down menu for Relay Output # to choose Relay Option 2.
- Scroll down to Option Relay Control and click Enable.
- Click Update at the top of the screen.
To configure a speed dial button to activate this second relay:
- Expand Station Settings and select Speed Dial/Favorites on the left-hand side menu.
- At the top of the screen, use the drop-down to select the station number of the master station to be configured under Select Station to Edit, and click Select.
- Use the drop-down menu for Speed Dial # to choose an available speed dial.
- Scroll down and click the radio button next to Option Relay Control.
- Click Open next to Station List and select the door station configured in the above steps and click OK.
- Click Update at the top of the screen.
Recommended Option
- Expand Function Settings and select Display Mode on the left-hand side menu.
- Under Standard Mode change the selected Home Screen to Option 2.
- Click Update at the top of the screen.
To upload the setting changes to each station, choose File(F) and select Upload Settings to Station.