External Signaling with the AX Master Station

You are here:
Estimated reading time: < 1 min

Summary

Steps on connecting an external signaling device such as a chime or bell to an AX master station.

 

Solution

Follow the diagram below using the 6-pin connector included with the AX master station.

Step 1

Connect Brown (V+) and Red (V-) to standard coax monitor / DVR input. The maximum wire run is 5’. Output is 1Vp-p, 75 Ω.

 

Step 2

Connect the Orange and Yellow wires to either an IER-2 chime extension speaker or the White and Blue wires on the RY-ES relay for external device signaling.

 

Step 3

Connect the Green and Blue wires to any normally open dry contact device, to be used in place of the talk button on the master. Contact device should be no more than 50’ from the master.

Was this article helpful?
Dislike 0
Views: 430