Modification
Adding another C-ML/A to an existing or new system.
Difficulty Level
2 – Easy/moderate – Component connection to external points.
Components Required
- DAK-2S: Dual master adapter kit
- Power: Each master requires its own power supply or 4 “C” sized batteries.
Instructions
- Install components as shown on the diagram.
- Only one master can be used at a time. A squelch tone will be heard if both master stations are on and the TALK button is pressed at either one.
- Sub station will call both masters simultaneously and either master can answer the calling station.
Diagram
Install the bare wire end of each component module in the DAK-2S to the “1” terminal of each C-ML/A master station.
Answer the call at ONE MASTER only. If the TALK button is pressed at both masters, activating the timing circuit on both, a loud squelch will be heard. Wait 15 seconds until the timing circuit resets before pressing TALK button again.